- Antimicrobial Testing
- ASTM G21 Fungal Tested. Does not support microbial growth. ASTM G22 Bacteria Tested. Does not support bacterial growth
- Flammability
- ASTM E84-08 Tested Surface Burning FSI=15, SDI=10, Class A; Passes ANSI Z124.1.2-2005 Cigarette Test; Passes ANSI Z124.1.2-2005 Ignition Test - Less than 30 seconds
- Flexural Strength
- ASTM D790-10A Flexural Strength Tested. 10,100 psi; ASTM D790-10A Flexural Modulus Tested. 1,434,000 psi
- Hardness
- ASTM D2583-07 Barcol Hardness - 67
- Light Blocking
- Unknown
- Lightfastness
- Pass ANSI Z124.1.2-2005 Color Fastness - 1.21. NEMA LD3-2000 Light Resistance (Xenon Arc) Tested. No Effect
- Maintenance
- Cleaning with soapy water or ammonia-based cleansers will remove most dirt and stains. Stubborn stains can be removed with a multi-surface cleaner, bleach, bleach-based cleansers or nonabrasive cleansers. Refer to Care and Maintenance document for more information
- Performance
- ANSI Z124.1.2-2005; Thermal Shock Resistance: Passes ANSI Z124.1.2-2005; Heat Deflection Temperature: ASTM D648-07 B ; NEMA LD3-2000 High Temperature Resistance Tested
- Stain Resistance
- Passes ANSI Z124.1.2-2005 Stain Resistance - 34 Rating
- Tensile Strength
- ASTM D638-10 Tensile Strength Tested. 45.9 MPa. ASTM D638-10 Elongation at Break Tested. 0.50%. ASTM D638-10 Tensile Modulus Tested. 9890 Mpa
- Water Absorption
- ASTM D570-98(2010) Water Absorption Tested. 0.10%